Evolving Home · Architect brief
Sample — 3-bed semi-detached (mock)
For your 118 m² semi project · BS8 1QU — Energy independence north star
Generated 09/07/2026, 08:26:38
Design brief summary
Preference-aligned pathway "Active Roof" — readiness not evaluated; preference order only (score unchanged).
Envelope targets
- walls: U ≤ 0.18 W/m²K (concept target)
- roof: U ≤ 0.12 W/m²K (concept target)
- airtightness: ≤ 1.0 ACH @ 50 Pa (design target)
- glazing: Balance g-value and Uw by orientation; avoid overglazing south façades
Risk flags
- [medium] Overglazing risk — Large unshaded south glazing increases overheating before heating load drops.
- [medium] Thermal bridge detailing — Junctions at balconies, corners, and extension ties need explicit psi-value strategy.
This pack is design-stage decision support from Evolving Home. It is not a SAP calculation, PHPP balance, HEM assessment, or Energy Performance Certificate. A qualified On Construction Domestic Energy Assessor (or PHPP consultant) must produce the authoritative compliance model for Building Regulations and/or Passive House certification.
Passive House (PHPP) certification and UK Building Regulations (SAP/HEM) are separate workflows. This brief supports early design intent only.
Assumptions ledger (compact)
Key assumptions, evidence gaps, and verification hooks for consultant handoff.
- Project assumptionsEstimated
For your 118 m² semi project · BS8 1QU — Energy independence north star
- Project assumptionsEstimated
Recommended pathway (preference-ranked): active roof — unknown
- Project assumptionsEstimated
Climate profile: Temperate (UK)
- Project assumptionsEstimated
2 storeys (design intent)
- Project assumptionsEstimated
Budget sensitivity: balanced
- Envelope & glazingEstimated
walls: U ≤ 0.18 W/m²K (concept target)
- Envelope & glazingEstimated
roof: U ≤ 0.12 W/m²K (concept target)
- Envelope & glazingEstimated
airtightness: ≤ 1.0 ACH @ 50 Pa (design target)
- Envelope & glazingEstimated
glazing: Balance g-value and Uw by orientation; avoid overglazing south façades
- Envelope & glazingEstimated
Glazing: ~18% floor area — balanced glazing
- Evidence gapsMissing
Loft depth / roof build-up not verified on site
- Evidence gapsMissing
No blower-door test scheduled — airtightness target is design intent only
Consultant handoff preview
Live previewPreview onlyProject assumptions
- ·For your 118 m² semi project · BS8 1QU — Energy independence north star
- ·Recommended pathway (preference-ranked): active roof — unknown
- ·Climate profile: Temperate (UK)
- ·2 storeys (design intent)
- ·Budget sensitivity: balanced
Envelope & glazing
- ·walls: U ≤ 0.18 W/m²K (concept target)
- ·roof: U ≤ 0.12 W/m²K (concept target)
- ·airtightness: ≤ 1.0 ACH @ 50 Pa (design target)
- ·glazing: Balance g-value and Uw by orientation; avoid overglazing south façades
- ·Glazing: ~18% floor area — balanced glazing
Evidence gaps
- ·Loft depth / roof build-up not verified on site
- ·No blower-door test scheduled — airtightness target is design intent only
Questions for SAP / HEM assessor
- ·Confirm notional vs actual specification path
- ·Overheating screening method for primary living rooms
- ·Renewable contribution accounting and battery assumptions
Questions for PHPP consultant
- ·Thermal bridge Psi-values for preferred junction details
- ·Heating/cooling load after fabric specification locked
- ·Ventilation summer bypass strategy with MVHR